Mayo Test ID 3FBLN Fibulin 3 Immunostain, Technical Component Only
Ordering Guidance
This test includes only technical performance of the stain (no pathologist interpretation is performed). If diagnostic consultation by a pathologist is required order PATHC / Pathology Consultation.
Shipping Instructions
Attach the green "Attention Pathology" address label (T498) and the pink Immunostain Technical Only label included in the kit to the outside of the transport container.
Specimen Required
Supplies: Immunostain Technical Only Envelope (T693)
Container/Tube: Immunostain Technical Only Envelope
Preferred:
-Formalin-fixed, paraffin-embedded tissue block
OR
-2 Unstained, positively charged glass slides (25- x 75- x 1-mm) per test ordered; sections 4-microns thick
Acceptable: None
Useful For
Identification and classification of amyloid types in tissue
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
IHTOI | IHC Initial, Tech Only | No | No |
IHTOA | IHC Additional, Tech Only | No | No |
Testing Algorithm
For the initial technical component only immunohistochemical (IHC) stain performed, the appropriate bill-only test ID will be reflexed and charged (IHTOI). For each additional technical component only IHC stain performed, an additional bill-only test ID will be reflexed and charged (IHTOA).
Method Name
Immunohistochemistry (IHC)
Reporting Name
Fibulin 3 IHC, Tech OnlySpecimen Type
TECHONLYSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
TECHONLY | Ambient (preferred) | ||
Refrigerated |
Reject Due To
Wet/frozen tissue Cytology smears Nonformalin fixed tissue Nonparaffin embedded tissue Noncharged slides ProbeOn slides Snowcoat slides |
Reject |
Clinical Information
Immunohistochemical staining for fibulin 3 (FBLN3), also known as epidermal growth factor-containing fibulin-like extracellular matrix protein 1 (EFEMP1), is useful in confirming amyloid type. Antibodies to FBLN3 stain the amyloid deposits in patients with FBLN3 amyloidosis. FBLN3 amyloidosis typically involves the venous walls in the gastrointestinal tract.
Interpretation
This test does not include pathologist interpretation, only technical performance of the stain. If interpretation is required, order PATHC / Pathology Consultation for a full diagnostic evaluation or second opinion of the case.
The positive and negative controls are verified as showing appropriate immunoreactivity. If a control tissue is not included on the slide, a scanned image of the relevant quality control tissue is available upon request; call 855-516-8404.
Interpretation of this test should be performed in the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Cautions
The charge of glass slides can be affected by environmental factors and subsequently may alter slide staining. Sending unsuitable glass slides can result in inconsistent staining due to poor slide surface chemistry.
Best practices for storage of positively charged slides:
-Minimize time slides are stored after being unpackaged
-Limit exposure to high humidity and heat
-Minimize exposure to plastics
Clinical Reference
1. Dao LN, Kurtin PJ, Smyrck TC, et al. The novel form of amyloidosis derived from EGF-containing fibulin-like extracellular matrix protein 1 (EFEMP1) preferentially affects the lower gastrointestinal tract of elderly females. Histopath. 2020 Oct 5. doi: 10.1111/his.14276 Epub ahead of print
2. Tasaki M, Ueda M, Hoshii Y, et al. A novel age-related venous amyloidosis derived from EGF-containing fibulin-like extracellular matrix protein 1. J Pathol. 2019;247(4):444-455
3. Magaki S, Hojat SA, Wei B, So A, Yong WH. An introduction to the performance of immunohistochemistry. Methods Mol Biol. 2019;1897:289-298. doi:10.1007/978-1-4939-8935-5_25
Method Description
Immunohistochemistry on sections of paraffin-embedded tissue.(Unpublished Mayo method)
Specimen Retention Time
Until staining is complete.Performing Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
88342-TC, primary
88341-TC, if additional IHC
LOINC Code Information
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
609272 | Fibulin 3 IHC, Tech Only | No LOINC Needed |
Day(s) Performed
Monday through Friday