Mayo Test ID BTIA1 T-Cell Intracellular Antigen 1 (TIA-1) Immunostain, Bone Marrow, Technical Component Only
Ordering Guidance
This test includes only technical performance of the stain (no pathologist interpretation is performed). If diagnostic consultation by a pathologist is required order PATHC / Pathology Consultation.
Shipping Instructions
Attach the green pathology address label and the pink Immunostain Technical Only label included in the kit to the outside of the transport container.
Specimen Required
Specimen Type: Tissue
Supplies: Immunostain Technical Only Envelope (T693)
Container/Tube: Immunostain Technical Only Envelope
Preferred:
-Formalin-fixed, paraffin-embedded tissue block
OR
-2 Unstained, positively charged glass slides (25- x 75- x 1-mm) per test ordered; sections 4-microns thick
Acceptable: None
Useful For
Characterizing neoplasms of cytotoxic T cells or natural killer cells
Reflex Tests
Test ID | Reporting Name | Available Separately | Always Performed |
---|---|---|---|
IHTOI | IHC Initial, Tech Only | No | No |
IHTOA | IHC Additional, Tech Only | No | No |
Method Name
Immunohistochemistry
Reporting Name
Bone Marrow TIA1 IHC, Tech OnlySpecimen Type
TECHONLYSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
TECHONLY | Ambient (preferred) | ||
Refrigerated |
Reject Due To
Wet/frozen tissue Cytology smears Nonformalin fixed tissue Nonparaffin embedded tissue Noncharged slides ProbeOn slides Snowcoat slides |
Reject |
Clinical Information
T-cell intracellular antigen 1 (TIA-1) shows a granular cytoplasmic staining pattern due to its presence in cytotoxic granules. It is involved in cytotoxic cell-mediated immune responses. TIA-1 was first identified in cytotoxic T cells; it is also expressed in normal natural killer (NK) cells and granulocytes.
Interpretation
This test does not include pathologist interpretation, only technical performance of the stain. If interpretation is required, order PATHC / Pathology Consultation for a full diagnostic evaluation or second opinion of the case.
The positive and negative controls are verified as showing appropriate immunoreactivity and documentation is retained at Mayo Clinic Rochester. If a control tissue is not included on the slide, a scanned image of the relevant quality control tissue is available upon request. Contact 855-516-8404.
Interpretation of this test should be performed in the context of the patient's clinical history and other diagnostic tests by a qualified pathologist.
Cautions
This test is optimized for use on B5-fixed, decalcified, paraffin-embedded bone marrow specimens.
Age of a cut paraffin section can affect immunoreactivity. Stability thresholds vary widely among published literature and are antigen dependent. Best practice is for paraffin sections to be cut within 6 weeks.
The charge of glass slides can be affected by environmental factors and subsequently may alter slide staining. Sending unsuitable glass slides can result in inconsistent staining due to poor slide surface chemistry.
Best practices for storage of positively charged slides:
-Minimize time slides are stored after being unpackaged
-Limit exposure to high humidity and heat
-Minimize exposure to plastics
Clinical Reference
1. Fujimura T, Furudate S, Kambayashi Y, Aiba S: Potential use of bisphosphonates in invasive extramammary Paget's disease: an immunohistochemical investigation. Clin Dev Immunol. 2013;2013(3):164982. doi: 10.1155/2013/164982
2. Kiyasu J, Aoki R, Tanaka PY, et al: FOXP3(+) regulatory and TIA-1(+) cytotoxic T lymphocytes in HIV-associated Hodgkin lymphoma. Pathol Int. 2012 Feb;62(2):77-83. doi: 10.1111/j.1440-1827.2011.02754.x
3. Zlobec I, Karamitopoulou E, Terracciano L, et al: TIA-1 cytotoxic granule-associated RNA binding protein improves the prognostic performance of CD8 in mismatch repair-proficient colorectal cancer. PLoS One. 2010 Dec 10;5(12):e14282. doi: 10.1371/journal.pone.0014282
Method Description
Immunohistochemistry on sections of paraffin-embedded tissue.(Unpublished Mayo method)
Day(s) Performed
Monday through Friday
Report Available
1 to 3 daysSpecimen Retention Time
Until staining is completePerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
88342-TC, primary
88341-TC, if additional IHC
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
BTIA1 | Bone Marrow TIA1 IHC, Tech Only | Order only;no result |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
605161 | Bone Marrow TIA1 IHC, Tech Only | Bill only; no result |